Induction Melting Furnace is the device converting three phase power current into single phase intermediate frequency current and enabling metal to produce eddy current loss through electromagnetic field induction to achieve heating and melting and is applicable to melting, heating or holding of steel, copper, aluminum, zinc, tin, nickel silver and other ferrous or nonferrous metal and alloy material, as well as heating treatment prior to forging, sintering and tube-bending forming in casting and melting industries.
Equipment Type |
Power input |
Power Output |
Melting time |
Electricity consumption
per ton of material (KW) |
(Furnace capacity) |
(three-phase four-wire 50/60HZ) |
(Minutes) |
|
Equipment power |
Incoming
line voltage |
Into the
line current |
Matching
transformer |
DC current |
DC voltage |
IF voltage |
IF frequency |
|
Steel |
Copper |
Aluminum |
|
(kw) |
(V) |
(A) |
(A) |
(V) |
(V) |
(Khz) |
|
GW--0.05T |
50 |
380 |
80 |
50 |
100 |
500 |
750 |
1 |
20-40 |
750 |
510 |
650 |
GW--0.1T |
100 |
380 |
160 |
100 |
200 |
500 |
750 |
1 |
20-40 |
700 |
510 |
640 |
GW--0.15T |
160 |
380 |
256 |
200 |
320 |
500 |
750 |
1 |
20-40 |
650 |
500 |
630 |
GW--0.25T |
200 |
380 |
320 |
250 |
400 |
500 |
750 |
1 |
20-45 |
650 |
500 |
610 |
GW--0.35T |
250 |
380 |
400 |
315 |
500 |
500 |
750 |
1 |
20-45 |
650 |
490 |
600 |
GW--0.5T |
350 |
380 |
560 |
400 |
700 |
500 |
750 |
0.8 |
30-50 |
630 |
480 |
570 |
GW--0.75T |
500 |
380 |
800 |
630 |
1000 |
500 |
750 |
0.8 |
40-50 |
620 |
470 |
560 |
GW--1T |
800 |
380 |
1280 |
1000 |
1600 |
500 |
750 |
0.7 |
40-50 |
620 |
460 |
550 |
750 |
656 |
1000 |
808 |
990 |
1480 |
GW--1.5T |
1000 |
380 |
800 |
1250 |
1000 |
500 |
750 |
0.7 |
40-60 |
600 |
450 |
540 |
750 |
820 |
1250 |
1010 |
990 |
1480 |
GW--2T |
1400 |
750 |
1148 |
1800 |
1414 |
990 |
1480 |
0.5 |
45-60 |
600 |
440 |
530 |
750 |
574 |
1800 |
707 |
990 |
1480 |
GW--3T |
2000 |
750 |
820 |
2500 |
1010 |
990 |
1480 |
0.5 |
50-70 |
580 |
430 |
520 |
GW--5T |
3000 |
950 |
1140 |
4000 |
1190 |
1260 |
1900 |
0.3 |
50-80 |
570 |
420 |
510 |
GW--10T |
6000 |
950 |
2280 |
8000 |
2380 |
1260 |
1900 |
0.3 |
50-90 |
560 |
410 |
490 |
GW--15T |
8000 |
950 |
1520 |
10000 |
1590 |
1260 |
1900 |
0.3 |
50-90 |
550 |
400 |
480 |
GW--20T |
10000 |
950 |
1900 |
12500 |
1980 |
1260 |
1900 |
0.25 |
50-90 |
530 |
400 |
470 |
GW--30T |
15000 |
950 |
2850 |
20000 |
2980 |
1260 |
1900 |
0.25 |
50-90 |
520 |
400 |
450 |
Advantages of Induction Melting Furnace:
1. This kind of furnace has the advantages of high melting efficiency, good power saving effect, compact structure and strong overload capacity.
2. The surrounding of the furnace is low temperature, smoke less, the working environment is good .
3. Simple operation and reliable operation.
4. Fast temperature heating-up, furnace temperature easy to control, high production efficiency.
Product Details:
Spare part 1:Thyristor
Brand: TECHSEM Group and CSR Group, the above two companies are leading thyristor manufacturing industry in China
Function: Stable, have strong ability to resist strong current, durable, not easy to damage
Spare part 2:Control circuit board
Brand: Hengyang Furnace, developed by our own R&D Team
Function: Double tested before production, carefully checking, have a great control on the quality, every customer comment its stablility.
Spare part 3:Induction coils
Induction coil installs in the central of the furnace, it has spiral body with rectangular empty brass circle around, the pipe center should be cooled with water. Copper bar outside induction coil will connect with water-cooling cable. The lining closes to induction coil, which made by burden.
Safety Protection:
• Main circuit short circuit protection
• Main circuit phase loss protection
• Main circuit phase fault protection
• SCR over-current protection
• SCR overvoltage protection
• Cooling water temperature protection
• Low water pressure protection
• Furnace leakage protection
• Intermediate frequency power failure protection
• Intermediate frequency electric furnace fault protection rate and increase the life obviously
Why Choose us?
1,Low power consumption
Large current system made of pure copper as conductive medium, the whole circuit with less resistance. Electrode arm shaped as copper-clad box type, resistance and heat can be reduced efficiently. Reasonable arrange of all conductive systems to minimize the resistance of every circuit.
2,Safety & Stability
Full set of hydraulic driving system equipped with accumulator to ensure stability of facilities in the operation process. Whist, equipments can go on the motion when there any emergency accidents happen.
3,High Power Factor
Our power factory could reach over 98%, which could greatly reduce the capacitor box quantities. However we still equip enough capacitor box quantities, which mean your furnace is much much more efficient.
4.High flexibility & Maximum simplicity of operation
HMI used in electrical automation control, interface simulates the real form of furnace, which make the operation more convenient. Mixing feedstock, charging feedstock, melting, tapping all the commands can be implemented by computer.
5.More Durable
We get 6 thyristors on the left, 8 on the right, so even if one thyristor is damaged, our furnace still could be continued use. But many other factories only get only 4 on the right,the whole equipment cannot be used anymore when one thyristor is damaged.
After-sales service:
a. Cooperate with guidance to check the buyer installation work;
b. Internal and electrical wiring connections between equipment;
c. Site commissioning;, according to the actual equipment adjust to the best state;
d. Direct buyer operating personnel to the correct use of operating equipment;
e. Guidance on site security considerations;
f. To guide the buyer maintenance personnel troubleshooting methods;
g. Provide equipment specification;
Supplier responsibility:
a. Cooperate with guidance to check the buyer installation work;
b. Internal and electrical wiring connections between equipment;
c. Site commissioning;, according to the actual equipment adjust to the best state;
d. Direct buyer operating personnel to the correct use of operating equipment;
e. Guidance on site security considerations;
f. To guide the buyer maintenance personnel simple troubleshooting methods;
g. Provide equipment specification;